DTC 71 - EBCM Fault: Notes
EBCM has self-diagnostics which can detect internal failure within module. EBCM also monitors supply voltage and integrity of EBCM harness connection.
DTC 71 will set when EBCM detects an internal fault or the pump motor supply circuit is open or shorted to ground (open fuse).
If a failure is detected and sets a DTC 71, anti-lock brake system is disabled and EBCM turns on ANTI-LOCK indicator for remainder of ignition cycle.
If failure is intermittent, EBCM will enable system at next ignition cycle and a history DTC 71 will be present.
NOTE:
Test numbers refer to numbers on diagnostic chart.
- Checks that fusible link "B" feeding pump motor relay is good.
- Checks for voltage from pump motor supply circuit using EBCM ground to complete circuit.
- Checks for good connections from the harness to the EBCM.
- Checks to see if fault was false. If DTC 71 resets, replace EBCM.