Code 66, A/C Pressure Sensor: Notes
A/C pressure sensor responds to changes in A/C refrigerant system high side pressure. PCM uses A/C compressor load input to determine engine idle speed. Sensor uses a 5-volt reference signal from PCM and returns an input signal to PCM on a separate line. Low pressure (zero psi) will return a signal of about .1 volt. High pressure will return a signal of about 4.6 volts.
NOTE:
Test numbers refer to numbers on diagnostic chart.
- Checks voltage signal from A/C pressure sensor to PCM. Normal voltage is 0.1-1.8 volts.
- Checks to see if high signal is from a shorted sensor or a short to voltage in circuit. Normally, disconnecting sensor would make a normal circuit go to nearly zero volts.
- Checks to see if low voltage signal is from sensor or circuit. Jumpering sensor signal circuit to 5-volt reference checks circuit, connections and PCM.