Lockout Function Inoperative
Disconnect master switch connector. Using test light connected to ground, backprobe master switch wiring harness connector Dark Blue wire terminal. If test light does not illuminate, replace master switch. Recheck system operation. If test light illuminates, repair short to battery in Dark Blue wire between master switch connector and window switch. Recheck system operation.