TCC Pulse Width Modulation Solenoid: Removal
- Remove the case side cover. See CASE SIDE COVER
. Disconnect and reposition the electrical connectors from the following:
- 2-3 Shift solenoid valve assembly.
- Fluid pressure manual valve position switch assembly. See Figure .
- Remove the oil pump bolts (206 and 207). Remove the oil pump from the valve body. See Fig 2 .
- Disconnect the torque converter clutch pulse width modulation (TCC PWM) solenoid electrical connector. See Remove the TCC PWM solenoid retaining clip (314F). See Fig 3 . Remove the TCC PWM solenoid (334).
CAUTION:
Do not remove the bolt (205) that holds the oil pump together. See Fig 1
.