Installation Procedure
CAUTION:
Refer to Fastener Caution .
NOTE:
DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory. Applying additional sealant affects the sensors ability to detect detonation.
- Install and tighten the knock sensor (1).
Tighten
Tighten the sensor to 25 N.m (18 lb ft).
- Connect the knock sensor electrical connector (1).
- Install the three-way catalytic converter. Refer to Three-Way Catalytic Converter Replacement (V6) .
- Lower the vehicle.