Diagnostic Fault Information
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| B+ | U1875* | U1875 | - | - |
| Ignition | U1875* | U1875* | - | - |
| Accessory Wake Up Serial Data | U1814, U1875* | U1875* | - | - |
| High Speed GMLAN Serial Data (+) | U0073* | U0073, U1875* | U0073* | - |
| High Speed GMLAN Serial Data (-) | U0073* | U0073, U1875* | U0073* | - |
| Ground | - | U1875* | - | - |
| * Other modules/DTCs may set with this fault and multiple symptoms including a no start condition may occur. | ||||