Removal Procedure
WARNING:
Refer to Brake Fluid Irritant Warning .
CAUTION:
Refer to Brake Fluid Effects on Paint and Electrical Components Caution .
- Prepare electronic brake control module for replacement. Refer to Control Module References .
- Turn the ignition to the OFF position.
- Remove the radiator surge tank clip (2).
- Remove the radiator surge tank (1).
Position the radiator surge tank (1) aside.
- Disconnect the electrical connector from the EBCM/EBTCM.
- Remove the 6 brake pipes (1, 2) from the BPMV.
- Remove the 2 BPMV bracket bolts (2).
- Remove the BPMV bracket assembly (1).
- Remove the 3 BPMV bracket bolts.
- Remove the BPMV (2).
- Remove the BPMV insulator (1) from the BPMV bracket (3).
NOTE:
Do NOT disconnect engine coolant hoses.
CAUTION:
Always connect or disconnect the wiring harness connector from the EBCM/EBTCM with the ignition switch in the OFF position. Failure to observe this precaution could result in damage to the EBCM/EBTCM.
NOTE:
Cap the brake pipe fittings to prevent brake fluid loss and contamination.