Sunroof Control Module Programming and Setup
"Manual" indicates the first switch detent.
"Express" indicates the second switch detent.
- Ensure that the electrical harness on the headliner is connected to the sunroof window motor.
- Put the ignition in the RUN position.
- Initialization (Normalization) - Press the "manual close switch" until window finds the hard stop and moves slightly back. After initialization "express open" is allowed but not "express close".
- Learn Process:
- Open the sunroof window with the express or manual open switch to the full open position and release the switch.
- Press the "Manual Open Switch" and hold for more then 10 seconds, DO NOT release the switch. The sunroof window will automatically begin to move to the full close position.
- During this time it is necessary to keep the switch active until the process completes.
- Verify the operation of the sunroof window.
- The Initialization/Teach Process is not complete if any of the following actions take place before the initialization cycle is done.
- The sunroof window switch is not held in the close position.
- The ignition and/or battery power has been removed.
- The window panel has not reached the closed position.
NOTE:
Calibration file will be automatically downloaded by Body Control housing, BCM.
NOTE:
"Manual close" is allowed and limited "manual open" is allowed.
The Initialization/Teach Process must be restarted if the procedure is not carried out completely.