Unsuccessful Programming Recovery
GMNA Regions: When SPS failure message E4489 occurs during programming or calibration, do not call TCSC immediately. Record at which point the failure occurred before it displayed the E4489 message. When this occurs, proceed to GTS. Download the appropriate vehicle configuration and select the Inflatable Restraint Sensing and Diagnostic Module. Under Identification Information, look at parameters: Software Module 1 Identifier and Software Module 2 Identifier. If either of these are populated with a value of 1 or more, replace the Inflatable Restraint Sensing and Diagnostic Module. Record these parameter values on the back of the job card.
Non GMNA Regions: When SPS displays message indicating that programming may fail and the programming event fails at 0%, replace the Inflatable Restraint Sensing and Diagnostic Module. Verify no other DTC's or issues exist with the module prior to replacement. Record all DTCs and relevant information on the back of the job card.
In the event of an interrupted or unsuccessful programming event, perform the following steps:
- Ignition ON. Ensure the control module, DLC and programming tool connections are secure and the SPS software is up to date.
- Verify the control module can be reprogrammed.
- If the control module cannot be reprogrammed
- Ignition OFF for one minute, ignition ON.
- Verify the control module can be reprogrammed.
- If the control module cannot be reprogrammed, replace the control module.
- Go to next step: If the control module can be reprogrammed.
- All OK.
- Go to next step: If the control module can be reprogrammed
- All OK.