Compressor Runs Continuously
- Disconnect yellow wire (brown wire on Buick models) from compressor relay connector and plug connector back on relay.
- If compressor still runs, replace relay.
- Be sure that 8-14 second delay functions. If delay fails to function, replace height sensor.
- If compressor stops, replace wire in connector, reconnect relay and go to step 2.
- Disconnect height sensor wiring.
- If compressor stops, replace height sensor.
- If compressor still runs, locate open in wire from terminal No. 3 to relay.
- Check height sensor time delay function.
- If no time delay, replace both sensor and relay.
- If time delay is good, check circuit between compressor relay and height sensor for intermittent grounding condition.
- Check for defective relay by tapping on case. If relay clicks, replace it.