Module Unlock Test No 1
- Disconnect keyless entry module connector. Using a voltmeter, measure voltage between connector terminal D1 (Orange wire) and ground. If battery voltage is not present, check for open circuit in Orange wire.
- If battery voltage is present, check voltage between connector terminals D1 (Orange wire) and D15 (Black wire). If battery voltage is not present, check for open circuit in Black wire. If battery voltage is present, go to MODULE UNLOCK TEST NO. 2.