Conditions For Setting Code
Code B119 will set if ignition is ON and signal voltage indicates more than 99% (open circuit) or less than 2% (shorted circuit). During time failure is present twilight sentinel will not make a dark/light decision. The measure of light reading BD44 will display actual sensor reading.