Engine Controls - Sensor Operating Range Charts: Introduction
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it will cause driveability problems.
NOTE:
Unless specified otherwise, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR SPECIFICATIONS
| Temperature F° (C°) | Ohms |
|---|---|
| -40 (-40) | 100,000 |
| 266 (130) | 70 |
MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR SPECIFICATIONS
| PSI (kPa) | Output Voltage |
|---|---|
| 13.8-15.2 (95-105) | 4.5-5.0 |
| 5.4-7.3 (37-50) | 0.5-0.9 |
OXYGEN (O2) SENSOR SPECIFICATIONS
| Mixture | Voltage |
|---|---|
| High O2 (Lean Mixture) | 0.1 Volts (100 Millivolts) |
| Low O2 (Rich Mixture) | 0.9 Volts (900 Millivolts) |
THROTTLE POSITION SENSOR SPECIFICATIONS
| Throttle Angle | Approximate Voltage |
|---|---|
| Closed Throttle | 0.5 |
| Full Open | 5.0 |