Code P132, Knock Sensor Circuit Failure: Notes
This test checks for knock sensor wiring problem. If circuit No. 496 becomes open or shorted, voltage will either increase to greater than 4.2 volts or drop to less than 0.3 volt. If either of these conditions are met for 0.4 second, Code P132 will set.