Right Front Window Is Inoperative At Master Switch,
OPERATES AT INDIVIDUAL SWITCH
Disconnect master switch connector. Turn ignition switch to RUN position. Connect test light between ground and Brown wire terminal at master switch connector. If test light is on, replace master switch. If test light is off, repair open in Brown wire between master switch and power window 25-amp circuit breaker.