One Window Is Inoperative From Individual Switch, Operates From Master Switch
- Turn ignition switch to RUN position. Using a test light, backprobe between ground and Brown wire (Pink wire on right front window) at inoperative switch connector. If test light is on, go to next step. If test light is off, repair open Dark Blue or Pink wire. See WIRING DIAGRAMS .
- Check inoperative window switch for poor connections. Repair as necessary. If connection is okay, replace inoperative window switch.