Test Description
The numbers below refer to the numbers in the diagnostic procedure.
- 3
This step tests for a short to battery positive voltage on the ignition 1 voltage circuit. When the ignition is turned OFF, the test light should not illuminate at the COIL/MDL fuse. - 18
The Spark Tester places a higher load, up to 25,000 volts, on the secondary ignition than a normal spark plug.