Removal Procedure
CAUTION:
Fuel Vapors can collect while servicing fuel system parts in enclosed areas such as a trunk. To reduce the risk of fire and increased exposure to vapors:
- Use forced air ventilation such as a fan set outside of the trunk.
- Plug or cap any fuel system openings in order to reduce fuel vapor formation.
- Clean up any spilled fuel immediately.
- Avoid sparks and any source of ignition.
- Use signs to alert others in the work area that fuel system work is in process.
- Remove the fuel sender assembly. Refer to Fuel Sender Assembly Replacement .
- Disconnect the fuel pump electrical connector.
- Remove the fuel level sensor electrical connector retaining clip.
- Disconnect the fuel level sensor electrical connector from under the fuel sender cover.
- Remove the fuel level sensor retaining clip.
- Squeeze the locking tangs and remove the fuel level sensor.