Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 2: Listen for an audible click when the automatic transmission shift lock control solenoid operates. Command both the ON and OFF states. Repeat the commands as necessary.
- 3: Tests for voltage at the ignition 1 voltage circuit of the automatic transmission shift lock control solenoid.
- 4: Verifies that the RCDLR is providing a ground to the automatic transmission shift lock control solenoid.
- 5: Tests if ground is constantly being applied to the automatic transmission shift lock control solenoid.
DTC B2710
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Automatic Transmission Shift Lock Control Schematics Connector End View Reference: Automatic Transmission Shift Lock Control Connector End Views or Keyless Entry Connector End Views |
|||
| 1 | Did you perform A Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 10 |
| 4 |
|
Go to Step 8 | Go to Step 5 |
| 5 | Does the test lamp remain illuminated? | Go to Step 6 | Go to Step 7 |
| 6 | Test the control circuit of the automatic transmission shift lock control solenoid for an open or short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 13 | Go to Step 9 |
| 7 | Test the control circuit of the automatic transmission shift lock control solenoid for a short to battery voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 13 | Go to Step 9 |
| 8 | Inspect for poor connections at the harness connector of the automatic transmission shift lock control solenoid. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 13 | Go to Step 11 |
| 9 | Inspect for poor connections at the harness connector of the remote control door lock receiver (RCDLR). Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 13 | Go to Step 12 |
| 10 | Repair the open or short to ground in the automatic transmission shift lock control voltage supply circuit. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 13 | - |
| 11 | Replace the automatic transmission shift lock control solenoid. Refer Floor Shift Control Replacement
in Automatic Transmission - 5L50E. Did you complete the replacement? |
Go to Step 12 | - |
| 12 | Replace the remote control door lock receiver (RCDLR). Refer to Remote Control Door Lock Receiver Replacement
in Keyless Entry. Did you complete the replacement? |
Go to Step 12 | - |
| 13 |
|
Go to Step 2 | System OK |