Relief Procedure
- Turn the ignition OFF.
- Disconnect the negative battery cable in order to avoid possible fuel discharge if an accidental attempt is made to start the engine. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
- Loosen the fuel filler cap in order to relieve the fuel tank vapor pressure.
- Remove the fuel injector sight shield. Refer to Fuel Injector Sight Shield Replacement in Engine Mechanical.
- Connect the J 34730-1A to the fuel pressure connection at the left front of the fuel rail. Wrap a shop towel around the fitting while connecting the gage in order to avoid spillage.
- Install the bleed hose of the gage into an approved container.
- Open the valve on the gage to bleed the system pressure. The fuel connections are now safe for servicing.
- Drain any fuel remaining in the gage into an approved container.
CAUTION:
Refer to BATTERY DISCONNECT CAUTION
in Cautions and Notices.