Circuit/System Testing
- Ignition OFF, disconnect the harness connector X1 at the APM.
- Ignition ON, verify that a test lamp illuminates between the wake up signal circuit terminal 3 and ground.
- If the test lamp does not illuminate, test the circuit for a short to ground or an open/high resistance.
- Ignition OFF and scan tool disconnected, verify that a test lamp does not illuminate between the signal circuit terminal 3 and ground.
- If the test lamp illuminates, test the circuit for a short to voltage.
- If all circuits test normal, replace the APM.