Circuit/System Testing
APM
- Ignition OFF, test for less than 1.0 Ω between the accessory DC power control module case and ground strap.
- If greater than the specified value, test the ground circuit for an open/high resistance.
- Disconnect harness connector X3 of the accessory DC power control module.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal A and ground.
- If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. If the circuit fuse is open, test the control circuits of the accessory DC power control module for a short to ground.
- Ignition OFF, disconnect harness connector X1 of the accessory DC power control module.
- Ignition ON, verify that a test lamp illuminates between the wake up signal circuit terminal 3 and ground.
- If the test lamp does not illuminate, test the wake up signal circuit for an open/high resistance or a short to ground. If the circuit tests normal, replace the serial data gateway module.
- If all circuits test normal, replace the accessory DC power control module.
PIM
- Ignition OFF, disconnect harness connector X1 of the drive motor generator power inverter module (PIM).
- Ignition ON, verify that a test lamp illuminates between each B+ circuit and ground.
- If the test lamp does not illuminate, test each B+ circuit for an open/high resistance. If the circuit fuse is open, test the control circuits of the PIM for a short to ground.
- Verify that a test lamp illuminates between the ignition circuit terminal 20 and ground.
- If the test lamp does not illuminate, test the ignition circuit for an open/high resistance. If the circuit fuse is open, test the control circuits of the PIM for a short to ground.
- Verify that a test lamp illuminates between the wake up signal circuit terminal 19 and ground.
- If the test lamp does not illuminate, test the wake up signal circuit for an open/high resistance or a short to ground. If the circuit tests normal, replace the serial data gateway module.
- If all circuits test normal, replace the drive motor generator power inverter module.