Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the shift lock control solenoid.
- Ignition ON, verify a test lamp illuminates between the B+ circuit terminal E and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or open/high resistance. If the circuit tests normal, test or replace the shift lock control solenoid.
- Connect a test lamp between the B+ circuit terminal E and control circuit terminal K.
- Depress and release the brake pedal several times. The test lamp should turn ON and OFF as commanded.
- If the test lamp is always ON, test the control circuit for short to ground. If the circuit tests normal, replace the RCDLR.
- If the test lamp is always OFF, test the control circuit for an open/high resistance or short to voltage. If the circuit test normal, replace the RCDLR.
- If all circuits test normal, test or replace the shift lock control solenoid.