Circuit/System Testing
- Verify that a test lamp illuminates between the G13 generator B+ terminal 1 X2 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF.
- Test for greater than 100 Ω between the B+ circuit and ground.
- If 100 Ω or less, repair the short to ground on the circuit.
- If greater than 100 Ω, replace the generator.
- If the test lamp illuminates
- Ignition OFF, disconnect the X1 harness connector at the generator, ignition ON.
- Test for 4.5-5.5 V between the control circuit terminal 1 X1 and ground.
- Ignition OFF, disconnect the harness connectors at the ECM.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- Test for less than 2 Ω in the control circuit end to end.
- If greater the 2 Ω, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the ECM.
- Ignition OFF, disconnect the harness connectors at the ECM, ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If greater than 1 V, repair the short to voltage on the circuit.
- If less than 1 V, replace the ECM.
- Test or replace the generator.