Circuit/System Testing
- Ignition OFF, test for less than 1.0 Ω between the drive motor generator power inverter module case and ground strap.
- If greater than the specified value, test the ground circuit for an open/high resistance.
- Ignition OFF, disconnect the harness connector X1 of the drive motor generator power inverter module.
- Ignition ON, verify that a test lamp illuminates between each of the following B+ circuit terminals and ground.
- Terminal 6 X1
- Terminal 7 X1
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit fuse is open, test the control circuits of the drive motor generator power inverter module for a short to ground. If the circuits test normal, replace the drive motor generator power inverter module.
- Ignition ON, verify that a test lamp illuminates between each ignition circuit terminal 20 X1 and ground.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit fuse is open, test the control circuits of the drive motor generator power inverter module for a short to ground. If the circuits test normal, replace the drive motor generator power inverter module.
- Ignition ON, verify that a test lamp illuminates between the wakeup circuit terminal 19 X1 and ground.
- If the test lamp does not illuminate, test the entire circuit for an open/high resistance or short to ground. If the circuits test normal, replace the serial data gateway (SDG) module.
- Ignition OFF, disconnect the harness connector X1 of the accessory DC power control module.
- Test for less than 2 Ω between the following powertrain serial data circuit terminals.
- Accessory DC power control module terminal 2 X1 and drive motor generator power inverter module terminal 25 X1
- Accessory DC power control module terminal 1 X1 and drive motor generator power inverter module terminal 24 X1
- If greater than the specified range, test the circuit for an open/high resistance.
- Ignition OFF, disconnect the harness connector X3 of the engine control module (ECM).
- Test for less than 2 Ω between the following powertrain serial data circuit terminals.
- Drive motor generator power inverter module terminal 11 X1 and ECM terminal 53 X3
- Drive motor generator power inverter module terminal 10 X1 and ECM terminal 33 X3
- If greater than the specified range, test the circuit for an open/high resistance.
- If all circuits test normal, replace the drive motor generator power inverter module.