Blower Motor Control Module Replacement

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2008 GMC Yukon XL, 2008 GMC Yukon, 2008 Chevrolet Tahoe, 2008 Chevrolet Suburban, and 2008 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: View Of Blower Motor Control Module & Screws
GM1696338Courtesy of GENERAL MOTORS CORP.
Callout Component Name

Preliminary Procedure

  1. Remove the I/P insulator panel. Refer to Instrument Panel Insulator Replacement (Except Cadillac) or Instrument Panel Insulator Replacement (Cadillac) .
  2. Disconnect the blower motor control module electrical connector.
1 Blower Motor Control Module Screw (Qty: 2)
NOTE: Refer to Fastener Notice .

Tighten:  1.5 N.m (13 lb in)

2 Blower Motor Control Module