Drive Motor Battery Charger Receptacle Replacement
| Callout | Component Name |
|---|---|
|
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed. The High Voltage Disabling procedure includes the following steps:
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
Failure to follow the procedures may result in serious injury or death. Preliminary Procedures
|
|
| 1 | Drive Motor Battery Charger Receptacle Fastener (Qty: 4)
CAUTION:
Refer to Fastener Caution . Tighten 12 (106 lb in) |
| 2 | Drive Motor Battery Charger Receptacle Procedure
|