LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2017 >> CT6 Plug-In >> Repair and Diagnosis >> Electrical >> Body Electrical >> Hybrid/EV System Controls >> Diagnostic Information and Procedures >> DC Power Conversion Test >> Circuit/System Verification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit/System Verification

  1. Vehicle OFF.
  2. Measure and record the C1 battery voltage at the C1 battery terminals. The C1 battery voltage should stabilize between 12.4 and 12.8 V within a few minutes of turning the vehicle OFF.
    • If within the specified range 
  3. Vehicle ON, accessories OFF.
  4. Measure and record the C1 battery voltage at the C1 battery terminals. The voltage should be at least 1 V greater than the voltage measured in step 1 but less than 15.6 V.
    • If not within the specified range 

      Refer to Circuit/System Testing.

    • If within the specified range 
  5. All OK.