Accessory DC Power Control Module Bracket Replacement
| Callout | Component Name |
|---|---|
| Preliminary Procedure Radiator Surge Tank Bracket Replacement (LGW LTG without HP9)Radiator Surge Tank Bracket Replacement (LTG with HP9) |
|
| 1 |
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed. Accessory DC Power Control Module Bracket Bolt [2x]The High Voltage Disabling procedure includes the following steps:
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
Failure to follow the procedures may result in serious injury or death.
CAUTION:
Refer to Fastener Caution Tighten 9 N.m (80 lb in) |
| 2 | Accessory DC Power Control Module Bracket Nut Tighten 9 N.m (80 lb in) |
| 3 | Accessory DC Power Control Module Bracket |