Fastener Specifications
Reusable Threaded Fastener Tightening Specifications
|
NOTE:
All fasteners listed in this table can be reused after removal.
|
|
|---|---|
| Application | Specification |
| Metric (English) | |
| Accessory DC Power Control Module Bolt | 22 N.m (16 lb ft) |
| Accessory DC Power Control Module Bracket Bolt | 9 N.m (80 lb in) |
| Accessory DC Power Control Module Bracket Nut | 9 N.m (80 lb in) |
| Accessory DC Power Control Module High Voltage Connector Protector Bolt | 9 N.m (80 lb in) |
| Drive Motor Power Inverter Module 3-Phase Cable Retainer Nut | 9 N.m (80 lb in) |
| Drive Motor Power Inverter Module 3-Phase Cable Terminal Bolt | 9 N.m (80 lb in) |
| Drive Motor Power Inverter Module Bracket Fastener | 22 N.m (16 lb ft) |
| Generator Cable to Accessory DC Power Control Module Nut | 12 N.m (106 lb in) |
| Ground Cable to Accessory DC Power Control Module Nut | 12 N.m (106 lb in) |
| Harness Ground Terminal Bolt | 9 N.m (80 lb in) |
| High Voltage Cable Connector Cover Bolt | 9 N.m (80 lb in) |
| Interface Control Module Bracket Bolt | 9 N.m (80 lb in) |