Plug-In Charging System Components
The high voltage battery charging system consists of four main components:
- The off-vehicle charging equipment:
- Drive motor battery charger cable, often referred to as the travel cord set
- Optional, permanent 230/240 V charge station
- The hybrid/EV battery charger receptacle, often referred to as the drive motor battery charger receptacle.
- The battery charger, often referred to as the drive motor battery charger.
- The hybrid/EV battery pack.
A variety of mechanical, visual, and audio indicators/devices are used to communicate with the user of the charging equipment.
Drive Motor Battery Charger Cable/Charge Station
The drive motor battery charger cable provided with the vehicle features a standard household electrical plug on one end and a plug designed to interface with the vehicles hybrid/EV battery charger receptacle on the other end. The drive motor battery charger cable features a charge current interrupt device with AC power and fault indicators, and it is stored in the vehicle's cargo area. An optional charge station is available for customers who want to reduce the amount of time needed to recharge. The optional charge station, if available, is hard-wired to a 230/240 V power supply and must be permanently mounted at the customer's location. The optional charge station features the same plug on the vehicle end as the drive motor battery charger cable.
The Drive Motor Battery Charger Cable Indicators and the Vehicle Indicators
The drive motor battery charger cable has two indicators, the AC Present Indicator and the Fault Indicator, which display its status.
- Solid green AC Present Indicator means AC voltage is present at the wall plug and there are no faults.
- Flashing green AC Present Indicator and solid red Fault Indicator means the electrical outlet or plug is faulty or overheated.
- Solid red Fault Indicator means the AC outlet does not have a proper ground and charging is not permitted for safety reasons.
- Flashing red Fault Indicator means there is a vehicle fault and the charger cable ground-fault circuit interrupter (GFCI) has tripped.
- Solid green AC Present Indicator and flashing red Fault Indicator means the charger cable has failed self-check.
The off-vehicle battery charging equipment is supervised and controlled by the hybrid/EV powertrain control module 2. The hybrid/EV powertrain control module 2 is the primary controller, and all diagnostic trouble codes will set in that module even though some of the diagnostics are actually run within the battery charger. Charging events can be delayed at customer request to take advantage of lower rates during non-peak hours. The status of charging events, including delays, is communicated to the user through visual indications, instrument panel mounted charge status indicator, and audio tones. The vehicle charge status indicator, located on the top middle of the instrument panel, will be short flashing green when the vehicle is charging under automatic control. The flash rate increases from one to four as the battery charges. It will be long flashing green if the charging is delayed and will begin later. It will be solid green when charging is complete. A solid yellow indicator means the vehicle is not able to accept a charge. If there is no indicator, the drive motor battery charger cable is not working properly or not connected.
Vehicle Receptacle
The vehicle receptacle, or hybrid/EV battery charger receptacle, is located behind the charging port door on the driver's side rear quarter panel. The receptacle is accessed by depressing and opening the receptacle door.
Battery Charger
The battery charger is a serviceable assembly containing several micro-processors and two separate high voltage chargers. One of the high voltage chargers is used while charging with a 120 V charge source, and both are used with a 230/240 V charge source. The battery charger is mounted beneath the vehicle under the hybrid/EV battery pack. DEX-COOL® coolant is used to ensure that the charger does not exceed its maximum designed operating temperature. The battery charger, along with the 14 V power module and the drive motor generator power inverter module, are cooled by a power electronics cooling loop, which is separate from other cooling systems.
12 V Battery Maintenance Mode
Battery Maintenance Mode is an automatic function that prevents deep discharge of the 12 V battery in specific circumstances. It is enabled when the drive motor battery charger cable is plugged into the hybrid/EV battery charger receptacle and the hybrid/EV battery pack is not being charged. Operation differs depending on whether the power mode is Vehicle Off or Vehicle in Service Mode.
With Vehicle Off, the 12 V battery is monitored at periodic intervals up to a maximum of 30 days. With Vehicle in Service Mode, the 12 V battery is monitored at periodic intervals up to a maximum of 60 hours. If voltage is low, the 12 V battery is charged by the 14 V power module using external power for up to four hours. This function is only intended to prevent a dead 12 V battery and does not provide a full charge. This is more efficient than continuously trickle charging, thus minimizing the usage of external power.
Under normal circumstances, with a 12 V battery that is charged when the vehicle is parked, Battery Maintenance Mode will simply monitor the voltage level, and no charging will be necessary. With Vehicle Off, Battery Maintenance Mode will maintain the 12 V battery for up to 30 days. For longer periods, refer to Owner Manual for instructions.