Ignition System: Testing: Module
- Turn ignition off. Remove distributor cap. Turn ignition on. Check voltage at ignition coil positive terminal, using a voltmeter. Voltage should be 12 volts.
- Check voltage at ignition coil negative terminal. Voltage should be 12 volts. Using a 1.5 volt dry cell battery, connect positive pole of battery to Pink wire terminal and negative pole to White wire terminal, for no more than 5 seconds.