Pressure Operated ELEC. Divert/ELEC. Switching (PEDES)
- When engine is cold, port solenoid should be energized, allowing airflow to exhaust ports.
- When engine is warming up, port switch should be de-energized (off) and converter solenoid should be energized, forcing airflow past the converter valve to the catalytic converter.
- On the divert mode, both solenoids are de-energized, which opens the converter valve, allowing air out to divert/relief tube to atmosphere. If valves are not operating as specified, check circuit to solenoids. Repair or replace components as necessary.