Code 13, Open Oxygen Sensor Circuit: Notes
When exhaust temperature is less than 600°F (316°C), O2 sensor is open and produces no voltage. An open sensor circuit or cold sensor will not allow system to entire closed loop.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Code 13 will set at normal operating temperature if at least 2 minutes have passed since engine start, Code 21 or 22 is not present, O2 signal voltage is steady at .35-.55 volt and throttle position sensor signal is greater than idle. All conditions must be met for at least one minute.
- This determines if fault is in O2 sensor, ECM or wiring.
- Use only a high-impedance Digital Volt-Ohmmeter (DVOM) while checking for continuity in signal and ground circuits. If ground circuit is open, voltage on signal circuit will be greater than .6 volt.