O2 Sensor Contamination
O2 sensor contamination, caused by silicone in certain fuels or use of improper RTV sealant, may cause a White-powdery coating to cover O2 sensor. The false high signal voltage produced (or low oxygen content sensed) is interpreted by ECM as a rich mixture, causing ECM to set Code 45.