Electric AIR Pump Relay
- Start engine. With engine operating in open loop, electric air pump should run and air should be coming out of electric air pump exhaust port.
- If electric air pump is operating, allow engine to idle for at least 3 minutes. With vehicle in closed loop (or about 3 minutes after start), PCM should de-energize electric air pump relay and electric air pump should stop. If this does not occur, go to next step. If air pump operates as described, relay is functioning properly.
- Remove air pump relay from fuse/relay block. Air pump should stop. If air pump stops, check or replace faulty relay. If air pump does not stop, check circuit to air pump for a short to battery voltage.