Charge Indicator Light Inoperative
- Perform charging system check. See CHARGING SYSTEM TEST .
- Disconnect generator connector. Using a fused jumper wire, connect generator harness connector terminal No. 2 (White/Red wire) to ground. See WIRING DIAGRAMS . If charge indicator light illuminates, go to next step. If charge indicator light does not illuminate, go to step 4.
- Remove generator and replace regulator. Recheck system.
- Check charge indicator light bulb. Replace as necessary. Using a fused jumper wire, connect (backprobe) instrument cluster connector terminal No. 1 (White/Red wire) to ground. See WIRING DIAGRAMS . Turn ignition on. If charge indicator light illuminates, go to next step. If charge indicator light does not illuminate, go to step 6.
- Repair open circuit in White/Red wire between instrument cluster and generator. Recheck system.
- Check for open circuit in Black/White wire between instrument cluster connector C1 terminal No. 2 and junction block connector C4 terminal No. 3. See WIRING DIAGRAMS . If wiring is okay, go to next step. If an open exists, go to step 8.
- Check instrument cluster printed circuit for poor connections or cracks. Repair or replace as necessary. Recheck system.
- Repair open circuit on Black/White wire between instrument cluster and junction block. Recheck system.