Field Coils Test
Using ohmmeter, measure resistance between positive brush holder and negative brush holder. If resistance is 5 ohms or less, brush holder is grounded and must be replaced.
Using ohmmeter, measure resistance between positive brush holder and negative brush holder. If resistance is 5 ohms or less, brush holder is grounded and must be replaced.