Charge Indicator Light Always On
- Perform charging system check. See CHARGING SYSTEM TEST . Go to next step.
- Disconnect generator connector. Turn ignition on. If charge indicator light does not illuminate, go to next step. If charge indicator light illuminates, go to step 4 .
- Repair or replace generator. See GENERATOR under REMOVAL & INSTALLATION. Recheck system.
- Check for short to ground on Yellow wire between instrument cluster connector C4 terminal No. 13 and generator connector terminal No. 1. See WIRING DIAGRAMS . If short to ground does not exist, go to next step. If short to ground exists, go to step 6 .
- Repair or replace instrument cluster printed circuit. See appropriate INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT. Recheck system.
- Repair short to ground on Yellow wire between instrument cluster and generator. Recheck system.