Code Enable Criteria
- Engine is running.
DTC sets when generator turn on signal circuit voltage is low while PCM is commanding generator on for more than 30 seconds.
Or
DTC sets when generator field duty cycle signal PWM is less than 5 percent and engine RPM is less than 2500 for more than 30 seconds.