Test B: Charge Indicator Always On
- If charging system check was performed, go to next step. If charging system check was not performed, go to TEST A: CHARGING SYSTEM TEST .
- Start engine. If battery charge indicator remains illuminated after 5 second bulb check, go to next step. If battery charge indicator does not remain illuminated, problem may be intermittent. Check wiring and connections, see PRELIMINARY INSPECTION under TROUBLE SHOOTING.
- Turn ignition switch to OFF position. Disconnect generator 3-pin harness connector. Turn ignition switch to RUN position. If charge indicator illuminates, go to next step. If charge indicator does not illuminate, go to TEST A: CHARGING SYSTEM TEST .
- Test for short to ground in charge indicator ground circuit. See WIRING DIAGRAMS . After repairs are made, go to next step.
- Operate system to verify repair. If condition is corrected, system is okay. If condition was not found and corrected, go to step 3 .