Test Description
The numbers below refer to the step numbers on the procedures.
- 1
Make sure that you perform the Inspection/Maintenance System Check before performing this test. Failure to do so may result in difficulty updating the status to YES. - 2
Preprogramming the scan tool will reduce the amount of time the oxygen sensor heaters operate while verifying the enable criteria. - 3
This step identifies a first failure of a type "B" DTC. A DTC only appears on the I/M System Status display when the DTC becomes a MIL illuminating DTC. This occurs on the second failure of a type "B" DTC. A first failure of a type "B" DTC will not allow the I/M System Status to update to YES. See DIAGNOSTIC AIDS . - 4
This step helps identify any unique or unusual criteria required to run the diagnostic test if the universal set procedure does not. See CONDITIONS FOR RUNNING . - 5
The I/M System Status only reports on whether or not a diagnostic has run, not the outcome of the test. If any emission related DTC sets after the tests are complete, the DTC will require diagnosis.