Installation Procedure
- Inspect the CKP sensor O-ring and lubricate with a mineral based grease.
- Insert the CKP sensor into the block.
- Install the CKP sensor bolt.
Tighten: Tighten the bolt to 8 N.m (71 lb in).
NOTE:
Refer to Fastener Notice
in Cautions and Notices.