Installation Procedure

    CAUTION: In order to reduce the risk of fire and personal injury, before connecting fuel pipe fittings, always apply a few drops of clean engine oil to the male pipe ends.
    This will ensure proper reconnection and prevent a possible fuel leak.
    During normal operation, the O-rings located in the female connector will swell and may prevent proper reconnection if not lubricated.
  1. Apply a few drops of clean engine oil to the male pipe end.
  2. Fig 1: Oiling Male Pipe Ends (Metal Collar)
    GM12784Courtesy of GENERAL MOTORS CORP.
  3. Push both sides of the fitting together to cause the retaining tabs to snap into place.
  4. Fig 2: Assembling Connectors (Metal Collar)
    GM12786Courtesy of GENERAL MOTORS CORP.
  5. Once installed, pull on both sides of the fitting to ensure that the connection is secure.
  6. Fig 3: Ensuring Connection (Metal Collar) Is Secure
    GM12787Courtesy of GENERAL MOTORS CORP.
  7. Tighten the fuel filler cap.
  8. Reconnect the negative battery cable. Refer toBattery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
  9. Inspect for leaks.
    1. Turn ON the ignition for 2 seconds.
    2. Turn OFF the ignition for 10 seconds.
    3. Turn ON the ignition.
    4. Inspect for fuel leaks.