Installation Procedure
- Install the TP sensor O-ring to the TP sensor.
- Install the TP sensor.
- Apply thread-locking compound LOCTITE® 262, GM P/N 12345493 (Canadian P/N 10953488) or equivalent to the TP sensor screws.
- Install the TP sensor screws.
Tighten: Tighten the screws to 2.0 N.m (18 lb in).
- Connect the TP sensor electrical connector.
- Connect the fuel lines. Refer to Quick Connect Fitting(s) Service (Metal Collar) .
NOTE: