Installation Procedure
- Install HO2S 2 (1) into the exhaust pipe below the catalytic converter.
Tighten: Tighten HO2S sensor to 45 N.m (32 lb ft).
- Lower the vehicle.
- Connect the HO2S 2 electrical connector.
NOTE:
Refer to Component Fastener Tightening Notice in Cautions and Notices.
IMPORTANT:
The new HO2S 1 comes with an antiseize coating on the sensor threads. Take precautions in order to prevent the removal of any of the antiseize coating prior to installation. If the sensor was removed and is being reinstalled, an antiseize compound must be applied to the threads before installation.
- Install HO2S 2 (1) into the exhaust pipe below the catalytic converter (1).
Tighten: Tighten HO2S sensor to 45 N.m (32 lb ft).
- Connect the HO2S 2 electrical connector.
- Lower the vehicle.
NOTE:
Refer to Component Fastener Tightening Notice in Cautions and Notices.
IMPORTANT:
The new HO2S 2 comes with an antiseize coating on the sensor threads. Take precautions in order to prevent the removal of any of the antiseize coating prior to installation. If the sensor was removed and is being reinstalled, an antiseize compound must be applied to the threads before installation.