LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 2005 >> SSR Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 140 (Computer/Integrating Systems) >> Diagnostic Information And Procedures >> Scan Tool Data List
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Scan Tool Data List

WARNING: This page is about a different car, the 2005 Saturn L300. However, it is still accessible from the selected car via links, so may be relevant.
ABS/TCS

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
ABS Fault Yes/No No
Battery 1 Volts Varies
Coolant Gauge Position % of Gauge Varies
Displayed Odometer km/miles Varies
Fuel Gauge Position % of Full Varies
Park Brake Switch On/Off On
Traction Active Yes/No No
Traction Control Status On/Off On
Traction LED Command On/Off On
Traction LED Feedback High/Low Low
Switch Inputs

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
A/C Request (RPO C60) Yes/No No
Battery 1 Volts Varies
Decklid Ajar Switch High/Low High
Driver Door Switch High/Low High
Front Wiper Delay Switch On/Off Off
High Beam Input=DRL Yes/No No
High Beam Input=High Yes/No No
High Beam Input=Off Yes/No Yes
Key In Ignition Yes/No Yes
Lock Switch On/Off Off
Low Beam Input = DRL (Late 2004) Yes/No No
Low Beam Input = High (Late 2004) Yes/No No
Low Beam Input = Off (Late 2004) Yes/No Yes
Low Beam Switch On/Off Off
Low Brake Fluid Yes/No No
Low Coolant Yes/No No
Oil Life Reset Switch High/Low High
Park Brake Switch On/Off On
Parklamp Switch On/Off Off
Pass Door Switches High/Low High
Rear Defog Relay Cmd. On/Off Off
Rear Defog Relay Fdbk. High/Low High
Rear Defog Switch (RPO C60) On/Off Off
Rear Wiper Switch On/Off Off
Shifter Unlock Cmd On/Off Off
Shifter Unlock Fdbk. High/Low High
Unlock Switch On/Off Off
Exterior Lamps

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
ALC Light Sensor Volts Varies
Battery 1 Volts Varies
DRL Relay Command On/Off Off
DRL Relay Feedback High/Low High
Headlamp Cmd. On/Off Off
Headlamp Fdbk. High/Low High
High Beam Input Volts Varies
High Beam Input=DRL Yes/No No
High Beam Input=High Yes/No No
High Beam Input=Off Yes/No Yes
Low Beam Input (Late 2004) Volts Varies
Low Beam Input = DRL (Late 2004) Yes/No No
Low Beam Input = High (Late 2004) Yes/No No
Low Beam Input = Off (Late 2004) Yes/No Yes
Low Beam Switch On/Off Off
Parklamp Cmd. On/Off Off
Parklamp Fdbk. High/Low High
Parklamp Input Volts Varies
Parklamp Switch On/Off Off
Interior Lamps

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
Battery 1 Volts Varies
Dome Lamp Command On/Off Off
Dome Lamp Feedback High/Low High
Driver Door Switch High/Low High
Key In Ignition Yes/No Yes
Inadvertent Power Cmd. On/Off On
Inadvertent Power Fdbk. High/Low High
I/P Dimmer Input Volts Varies
I/P Dimmer Output % DC Varies
Pass Door Switches High/Low High
Door Locks

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
Battery 1 Volts Varies
Driver Unlock Relay Cmd. On/Off Off
Driver Unlock Relay Fdbk. High/Low Low
Lock All Relay Cmd. On/Off Off
Lock All Relay Fdbk. High/Low Low
Lock Switch On/Off Off
Remote Lock Command Yes/No No
Remote Panic Command Yes/No No
Remote Trunk Command Yes/No No
Remote Unlock Command Yes/No No
Pass Unlock Relay Cmd. On/Off Off
Pass Unlock Relay Fdbk. High/Low Low
Trunk Release Sol. Cmd. On/ Off Off
Trunk Release Sol. Fdbk. High/Low Low
Trunk Release Switch On/Off Off
Unlock Switch On/Off Off
Wiper/Washer

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
Battery 1 Volts Varies
Front Washer Motor Input On/Off Off
Front Wiper Delay Relay Cmd. On/Off Off
Front Wiper Delay Relay Fdbk. High/Low High
Front Wiper Delay Switch On/Off Off
Rear Washer Motor Input On/Off Off
Rear Wiper Relay Cmd. On/Off Off
Rear Wiper Relay Fdbk. High/Low Low
Rear Wiper Switch On/Off Off
Washer Fluid Level Low/OK Ok
Wiper Delay Input Volts Varies
Wiper Delay 1 Yes/No Varies
Wiper Delay 2 Yes/No Varies
Wiper Delay 3 Yes/No Varies
Security Data

Scan Tool Parameter Units Displayed Typical Data Value
Operating Conditions: Ignition in RUN Position, Engine OFF, All Doors Closed, Park Brake Applied (DRLs OFF)
Accessory High/Low High
Auto-Learn Timer Seconds Varies
Battery 1 Volts Varies
Decklid Ajar Switch High/Low High
Horn Relay Command On/Off Off
Horn Relay Feedback High/Low High
Ignition 1 Input High/Low High
Key Learned No Yes
Key Learn Enabled Yes/No Yes
Passlock Input Volts Varies
Passlock Power Fdbk. High/Low High
Passlock Timer Seconds Varies
Security LED On/Off/Flash Off
Trunk Release Switch On/Off Off