Installation Procedure
- Install the TP sensor O-ring on the TP sensor.
- Install the TP sensor on the throttle body assembly.
- Install the 2 TP sensor fasteners, using a thread-locking compound on the screws. Loctite® 262, GM P/N #1052624, or equivalent should be used.
Tighten: Tighten the TP sensor attaching screws to 2 N.m (18 lb in).
- Connect the TP sensor electrical connector.
- Connect the evaporative emission (EVAP) purge line.
- Connect the fuel lines. Refer to Quick Connect Fitting(s) Service (Metal Collar) .
- Install the air intake duct. Refer to Air Cleaner Intake Duct Replacement .
NOTE:
Refer to Fastener Notice in Cautions and Notices.