Calibration Criteria

WARNING: This page is about a different car, the 2006 Chevrolet Monte Carlo and 2006 Chevrolet Impala. However, it is still accessible from the selected car via links, so may be relevant.

The brake pedal position sensor (BPPS) receives a low reference signal and a 10-volt reference signal from the body control module (BCM). Whenever the brake pedal is applied, the brake pedal position sensor applies a variable voltage signal to the BCM through the stop lamp switch signal circuit. Brake pedal position sensor calibration must be performed after the brake pedal position sensor or BCM have been serviced. The calibration procedure will set brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying the brake system and to provide this information to the vehicle subsystems via the class 2 communication bus.