Circuit/System Testing
- Verify none of the following conditions exist:
- If you find any of the above conditions, repair as necessary.
- Ignition OFF, disconnect the harness connector at the heated oxygen sensor (HO2S) 2.
- Ignition ON, test for less than 0.1 volt between the low reference circuit terminal 1 and ground.
- If greater than the specified range, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the signal circuit terminal 4 and the low reference circuit terminal 1. Verify the appropriate HO2S parameter is less than 60 mV.
- If greater than the specified range, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the HO2S.